CVE-2017-12718 in the critical feed json

A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6.

published 2018-02-15 8 y ago modified 2026-06-17 4 mo ago also EUVD-2017-4257

cvss
8.1
version 3.0, NVD
cisa kev
Not listed
not in CISA's catalog
epss
12.8%
EPSS 12.8% chance of exploitation in 30 days, percentile 96%
public exploits
1
Exploit-DB

Summary

A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation.

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-17-285-04A updated cvss 8.1

NXP Semiconductors MQX RTOS (Update A)

  • NXP Semiconductors MQX RTOS <= 4.1, <= 5.0
    affected: mitigation “NXP released MQX, Version 5.1 on January 31, 2018, which addresses both vulnerabilities.”

From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf

cisa ICSMA-17-250-02A updated cvss 3.7

Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Vulnerabilities (Update A)

From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf

Timeline

  1. First public exploit (EDB-43776)
  2. Published

Exploit prediction

12.78% chance of exploitation in the next 30 days, higher than 96% of all scored CVEs (FIRST EPSS, 2026-11-08).

Exploits and checks

  • EDB-43776 Smiths Medical Medfusion 4000 - 'DHCP' Denial of Service dos, 2018-01-18

CVSS scores

assigned by version score vector
NVD 3.0 8.1 CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
NVD 2.0 6.8 AV:N/AC:M/Au:N/C:P/I:P/A:P

Affected products

  • n/a Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump

Classification

Weakness
  • CWE-120 Buffer Copy without Checking Size of Input
  • CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer