CVE-2017-10606 json
SRX Series: Cryptographic weakness in SRX300 Series TPM Firmware
published 2017-10-13 9 y ago modified 2026-06-17 4 mo ago also EUVD-2017-2253
- cvss
- 4.4
- version 3.0, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.3%
- EPSS 0.3% chance of exploitation in 30 days, percentile 25%
- public exploits
- 0
- none known
Summary
Version 4.40 of the TPM (Trusted Platform Module) firmware on Juniper Networks SRX300 Series has a weakness in generating cryptographic keys that may allow an attacker to decrypt sensitive information in SRX300 Series products. The TPM is used in the SRX300 Series to encrypt sensitive configuration data. While other products also ship with a TPM, no other products or platforms are affected by this vulnerability. Customers can confirm the version of TPM firmware via the 'show security tpm status' command. This issue was discovered by an external security researcher. No other Juniper Networks products or platforms are affected by this issue.
Exploit prediction
0.32% chance of exploitation in the next 30 days, higher than 25% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.0 | 4.4 | CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N |
| NVD | 3.0 | 4.4 | CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N |
| NVD | 2.0 | 2.1 | AV:L/AC:L/Au:N/C:P/I:N/A:N |
Affected products
- Juniper Networks Junos OS
References
-
kb.juniper.net
/JSA10809
vendor-advisory
Sources
- CVE List CVE-2017-10606
- NVD CVE-2017-10606
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.