An issue was discovered in SMA Solar Technology products.
published 2017-08-05 9 y ago modified 2026-06-17 4 mo ago also EUVD-2017-18774
- cvss
- 7.5
- version 3.0, NVD
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 1.5%
- EPSS 1.5% chance of exploitation in 30 days, percentile 74%
- public exploits
- 0
- none known
Summary
An issue was discovered in SMA Solar Technology products. An attacker can change the plant time even when not authenticated in any way. This changes the system time, possibly affecting lockout policies and random-number generators based on timestamps, and makes timestamps for data analysis unreliable. NOTE: the vendor reports that this is largely irrelevant because it only affects log-entry timestamps, and because the plant time would later be reset via NTP. (It has never been the case that a lockout policy or random-number generator was affected.) Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
Exploit prediction
1.51% chance of exploitation in the next 30 days, higher than 74% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| NVD | 3.0 | 7.5 | CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N |
| NVD | 2.0 | 5.0 | AV:N/AC:L/Au:N/C:N/I:P/A:N |