Skip to content
Fencer Vulns
critical 9.8

CVE-2017-9859 json

An issue was discovered in SMA Solar Technology products.

published 2017-08-05 9 y ago modified 2026-06-17 4 mo ago also EUVD-2017-18769

cvss
9.8
version 3.0, NVD
cisa kev
Not listed
not in CISA's catalog
epss
1.1%
EPSS 1.1% chance of exploitation in 30 days, percentile 66%
public exploits
0
none known

Summary

An issue was discovered in SMA Solar Technology products. The inverters make use of a weak hashing algorithm to encrypt the password for REGISTER requests. This hashing algorithm can be cracked relatively easily. An attacker will likely be able to crack the password using offline crackers. This cracked password can then be used to register at the SMA servers. NOTE: the vendor's position is that "we consider the probability of the success of such manipulation to be extremely low." Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected

Exploit prediction

1.13% chance of exploitation in the next 30 days, higher than 66% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
NVD 3.0 9.8 CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
NVD 2.0 5.0 AV:N/AC:L/Au:N/C:P/I:N/A:N

Classification

Weakness
  • CWE-327 Use of a Broken or Risky Cryptographic Algorithm

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.