high 7.3

CVE-2016-9334 json

An issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 controller 1763-L16AWA, Series A and B, Version 14.000 and pri…

published 2017-02-13 9 y ago modified 2026-06-17 4 mo ago also EUVD-2016-10144

cvss
7.3
version 3.0, NVD
cisa kev
Not listed
not in CISA's catalog
epss
4.1%
EPSS 4.1% chance of exploitation in 30 days, percentile 90%
public exploits
0
none known

Summary

An issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 controller 1763-L16AWA, Series A and B, Version 14.000 and prior versions; 1763-L16BBB, Series A and B, Version 14.000 and prior versions; 1763-L16BWA, Series A and B, Version 14.000 and prior versions; and 1763-L16DWD, Series A and B, Version 14.000 and prior versions. User credentials are sent to the web server in clear text, which may allow an attacker to discover the credentials if they are able to observe traffic between the web browser and the server.

Exploit prediction

4.06% chance of exploitation in the next 30 days, higher than 90% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
NVD 3.0 7.3 CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
NVD 2.0 5.0 AV:N/AC:L/Au:N/C:P/I:N/A:N

Affected products

  • n/a Rockwell Automation MicroLogix 1100 and 1400

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.