CVE-2017-12718 in the critical feed json
A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6.
published 2018-02-15 8 y ago modified 2026-06-17 4 mo ago also EUVD-2017-4257
- cvss
- 8.1
- version 3.0, NVD
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 12.8%
- EPSS 12.8% chance of exploitation in 30 days, percentile 96%
- public exploits
- 1
- Exploit-DB
Summary
A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation.
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-17-285-04A updated cvss 8.1
NXP Semiconductors MQX RTOS (Update A)
-
NXP Semiconductors MQX RTOS <= 4.1, <= 5.0affected: mitigation “NXP released MQX, Version 5.1 on January 31, 2018, which addresses both vulnerabilities.”
From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf
cisa ICSMA-17-250-02A updated cvss 3.7
Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Vulnerabilities (Update A)
-
Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump 1.1, 1.6, 1.5affected: vendor fix smiths-medical.custhelp.com
From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf
Timeline
- First public exploit (EDB-43776)
- Published
Exploit prediction
12.78% chance of exploitation in the next 30 days, higher than 96% of all scored CVEs (FIRST EPSS, 2026-11-08).
Exploits and checks
- EDB-43776 Smiths Medical Medfusion 4000 - 'DHCP' Denial of Service dos, 2018-01-18
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| NVD | 3.0 | 8.1 | CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H |
| NVD | 2.0 | 6.8 | AV:N/AC:M/Au:N/C:P/I:P/A:P |
Affected products
- n/a Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump
Classification
References
-
exploit-db.com
/exploits/43776/
exploit, third-party-advisory, vdb-entry
-
ics-cert.us-cert.gov
/advisories/ICSMA-17-250-02A
third-party-advisory, us-government-resource
-
securityfocus.com
/bid/101252
vdb-entry, third-party-advisory
-
securityfocus.com
/bid/100665
vdb-entry, third-party-advisory
Sources
- CVE List CVE-2017-12718
- NVD CVE-2017-12718
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.