CVE-2020-7580 json
A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1…
published 2020-06-10 6 y ago modified 2026-06-17 4 mo ago also EUVD-2020-28705
- cvss
- 6.7
- version 3.1, NVD
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.5%
- EPSS 0.5% chance of exploitation in 30 days, percentile 40%
- public exploits
- 0
- none known
Summary
A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.
Patch / fix
- siemens simatic_net_pc 16
- siemens simatic_s7-1500_software_controller 21.8
- siemens simatic_step_7 5.6
- siemens simatic_wincc 7.4
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-20-161-04 updated cvss 8.8
Siemens SIMATIC, SINAMICS, SINEC, SINEMA, SINUMERIK (Update J)
-
Siemens SIMATIC Automation Tool <V4_SP2affected: vendor fix, mitigation support.industry.siemens.com
-
Siemens SIMATIC NET PC Software V14 <V14_SP1_Update_14affected: fixed in V14, mitigation support.industry.siemens.com
-
Siemens SIMATIC NET PC Software V15affected: mitigation, no fix planned
-
Siemens SIMATIC NET PC Software V16 <V16_Upd3affected: fixed in V16, mitigation support.industry.siemens.com
-
Siemens SIMATIC PCS neo <V3.0_SP1affected: fixed in V3.0, mitigation
-
Siemens SIMATIC ProSave <V17affected: fixed in V17, mitigation
-
Siemens SIMATIC S7-1500 Software Controller <V21.8affected: fixed in V21.8, mitigation support.industry.siemens.com
-
Siemens SIMATIC STEP 7 (TIA Portal) V13 <V13_SP2_Update_4affected: fixed in V13, mitigation support.industry.siemens.com
show 18 moreshow fewer
-
Siemens SIMATIC STEP 7 (TIA Portal) V14 <V14_SP1_Update_10affected: fixed in V14, mitigation support.industry.siemens.com
-
Siemens SIMATIC STEP 7 (TIA Portal) V15 <V15.1_Update_5affected: fixed in V15.1, mitigation support.industry.siemens.com
-
Siemens SIMATIC STEP 7 (TIA Portal) V16 <V16_Update_2affected: fixed in V16, mitigation support.industry.siemens.com
-
Siemens SIMATIC STEP 7 V5 <V5.6_SP2_HF3affected: fixed in V5.6, mitigation support.industry.siemens.com
-
Siemens SIMATIC WinCC OA V3.16 <V3.16_P018affected: fixed in V3.16, mitigation winccoa.com
-
Siemens SIMATIC WinCC OA V3.17 <V3.17_P003affected: fixed in V3.17, mitigation winccoa.com
-
Siemens SIMATIC WinCC Runtime Advanced <V16_Update_2affected: fixed in V16, mitigation support.industry.siemens.com
-
Siemens SIMATIC WinCC Runtime Professional V13 <V13_SP2_Update_4affected: fixed in V13, mitigation support.industry.siemens.com
-
Siemens SIMATIC WinCC Runtime Professional V14 <V14_SP1_Update_10affected: fixed in V14, mitigation support.industry.siemens.com
-
Siemens SIMATIC WinCC Runtime Professional V15 <V15.1_Update_5affected: fixed in V15.1, mitigation support.industry.siemens.com
-
Siemens SIMATIC WinCC Runtime Professional V16 <V16_Update_2affected: fixed in V16, mitigation support.industry.siemens.com
-
Siemens SIMATIC WinCC V7.4 <V7.4_SP1_Update_14affected: fixed in V7.4, mitigation support.industry.siemens.com
-
Siemens SIMATIC WinCC V7.5 <V7.5_SP1_Update_3affected: fixed in V7.5, mitigation support.industry.siemens.com
-
Siemens SINAMICS Startdrive <V16_Update_3affected: fixed in V16, mitigation support.industry.siemens.com
-
Siemens SINAMICS STARTER <V5.4_HF2affected: fixed in V5.4, mitigation support.industry.siemens.com
-
Siemens SINEC NMS <V1.0_SP2affected: fixed in V1.0, mitigation support.industry.siemens.com
-
Siemens SINEMA Server <V14_SP3affected: fixed in V14, mitigation support.industry.siemens.com
-
Siemens SINUMERIK ONE virtual <V6.14 Siemens SINUMERIK Operate <V6.14affected: fixed in V6.14, mitigation
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
Exploit prediction
0.46% chance of exploitation in the next 30 days, higher than 40% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| NVD | 3.1 | 6.7 | CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H |
| NVD | 2.0 | 7.2 | AV:L/AC:L/Au:N/C:C/I:C/A:C |
Affected products
- Siemens SIMATIC Automation Tool
- Siemens SIMATIC NET PC Software V14
- Siemens SIMATIC NET PC Software V15
- Siemens SIMATIC NET PC Software V16
- Siemens SIMATIC PCS neo
- Siemens SIMATIC ProSave
- Siemens SIMATIC S7-1500 Software Controller
- Siemens SIMATIC STEP 7 (TIA Portal) V13
- Siemens SIMATIC STEP 7 (TIA Portal) V14
- Siemens SIMATIC STEP 7 (TIA Portal) V15
- Siemens SIMATIC STEP 7 (TIA Portal) V16
- Siemens SIMATIC STEP 7 V5
- Siemens SIMATIC WinCC OA V3.16
- Siemens SIMATIC WinCC OA V3.17
- Siemens SIMATIC WinCC Runtime Advanced
- Siemens SIMATIC WinCC Runtime Professional V13
- Siemens SIMATIC WinCC Runtime Professional V14
- Siemens SIMATIC WinCC Runtime Professional V15
- Siemens SIMATIC WinCC Runtime Professional V16
- Siemens SIMATIC WinCC V7.4
- Siemens SIMATIC WinCC V7.5
- Siemens SINAMICS STARTER
- Siemens SINAMICS Startdrive
- Siemens SINEC NMS
- Siemens SINEMA Server
- Siemens SINUMERIK ONE virtual
- Siemens SINUMERIK Operate
Classification
- Weakness
-
- CWE-428 Unquoted Search Path or Element
References
-
cert-portal.siemens.com
/productcert/pdf/ssa-312271.pdf
vendor-advisory
-
us-cert.cisa.gov
/ics/advisories/icsa-20-161-04
third-party-advisory, us-government-resource
Sources
- CVE List CVE-2020-7580
- NVD CVE-2020-7580
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.