CVE-2019-10955 json
In Rockwell Automation MicroLogix 1400 Controllers Series A, All Versions Series B, v15.002 and earlier, MicroLogix 1100 Controllers v14.00…
published 2019-04-25 7 y ago modified 2026-06-17 4 mo ago also EUVD-2019-2669
- cvss
- 6.1
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 3.0%
- EPSS 3.0% chance of exploitation in 30 days, percentile 87%
- public exploits
- 0
- none known
Summary
In Rockwell Automation MicroLogix 1400 Controllers Series A, All Versions Series B, v15.002 and earlier, MicroLogix 1100 Controllers v14.00 and earlier, CompactLogix 5370 L1 controllers v30.014 and earlier, CompactLogix 5370 L2 controllers v30.014 and earlier, CompactLogix 5370 L3 controllers (includes CompactLogix GuardLogix controllers) v30.014 and earlier, an open redirect vulnerability could allow a remote unauthenticated attacker to input a malicious link to redirect users to a malicious site that could run or download arbitrary malware on the user’s machine.
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-19-113-01 updated cvss 7.1
Rockwell Automation MicroLogix 1400 and CompactLogix 5370 Controllers
-
Rockwell Automation CompactLogix 5370 L1 controllers <= 30.014 Rockwell Automation CompactLogix 5370 L2 controllers <= 30.014 Rockwell Automation CompactLogix 5370 L3 controllers <= 30.014 Rockwell Automation MicroLogix 1100 Controllers <= 14.00 Rockwell Automation MicroLogix 1400 Controllers Series A Rockwell Automation MicroLogix 1400 Controllers Series B <= 15.002affected: mitigation “Rockwell Automation has released a security advisory with mitigation steps that can be found at:” rockwellautomation.custhelp.com
From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- partial
- Assessed
- 5 mo ago
Exploit prediction
3.03% chance of exploitation in the next 30 days, higher than 87% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CISA ADP | 3.1 | 6.1 | CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N |
| CNA | 3.1 | 6.1 | CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N |
| NVD | 3.0 | 6.1 | CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N |
| NVD | 2.0 | 5.8 | AV:N/AC:M/Au:N/C:P/I:P/A:N |
Affected products
- Rockwell Automation MicroLogix 1400 Controllers
- Rockwell Automation MicroLogix 1100 Controllers
- Rockwell Automation CompactLogix 5370 L1 controllers
- Rockwell Automation CompactLogix 5370 L2 controllers
- Rockwell Automation CompactLogix 5370 L3 controllers
Classification
- Weakness
-
- CWE-601 URL Redirection to Untrusted Site
References
-
ics-cert.us-cert.gov
/advisories/ICSA-19-113-01
third-party-advisory, us-government-resource
-
securityfocus.com
/bid/108049
vdb-entry, third-party-advisory
Sources
- CVE List CVE-2019-10955
- NVD CVE-2019-10955