Skip to content
Fencer Vulns
low 3.7

CVE-2026-93394 json

libmongoc SCRAM client nonce-validation bypass

published 2026-09-17 52 d ago modified 2026-09-25 44 d ago also EUVD-2026-82438

cvss
3.7
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.3%
EPSS 0.3% chance of exploitation in 30 days, percentile 25%
public exploits
0
none known

Summary

A flaw in libmongoc's SCRAM authentication implementation caused the client to continue the authentication handshake and transmit the client proof even when a nonce mismatch was detected in the server's first message. An unauthorized party with a man-in-the-middle position could exploit this by injecting a crafted server-first-message containing a controlled salt and low iteration count, then capturing the resulting client proof to perform offline password cracking. This vulnerability is mitigated by TLS, which is standard in production deployments.

Patch / fix

  • MongoDB Inc. C Driver 2.3.2
  • mongo-c-driver Debian 14 2.4.0-1

debian advisories DEBIAN-CVE-2026-93394

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

red hat product security vex CVE-2026-93394 updated cvss 5.9

libmongoc: libmongoc: Offline password cracking via SCRAM authentication bypass

  • Red Hat All currently supported Red Hat products
    not affected: vulnerable code not present

Red Hat CSAF VEX © Red Hat, Inc., from https://security.access.redhat.com/data/csaf/v2/vex/; changed: reduced to product statuses and remediations. CC BY 4.0 · csaf

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
partial
Assessed
52 d ago

Exploit prediction

0.32% chance of exploitation in the next 30 days, higher than 25% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 4.0 6.3 CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N
CNA 3.1 3.7 CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N
CNA 4.0 6.3 CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Affected products

  • MongoDB Inc. C Driver

Classification

Weakness
  • CWE-303 Incorrect Implementation of Authentication Algorithm

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.