Skip to content
Fencer Vulns
medium 5.9

CVE-2026-93317 json

Container blob cache can accept unverified content

published 2026-10-05 34 d ago modified 2026-10-06 34 d ago also EUVD-2026-92529

cvss
5.9
version 4.0, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.2%
EPSS 0.2% chance of exploitation in 30 days, percentile 5%
public exploits
0
none known

Summary

An unauthenticated attacker controlling a registry or OCI-layout blob source could provide blob contents that did not match the claimed digest. The resulting snapshot could be cached under that digest and reused by a later victim build, compromising build-input integrity.

Patch / fix

  • moby BuildKit 0.33.1

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

red hat product security vex CVE-2026-93317 updated cvss 6.5

github.com/moby/buildkit: BuildKit: Build integrity compromise via unvalidated blob digest caching

  • Red Hat Quay 3 quay/quay-builder-rhel8, quay/quay-builder-rhel9
    affected: workaround, no fix available “Fix deferred”
  • Red Hat Hardened Images podman 6.1.3-1.hum1, buildah 1.45.1-1.hum1, trivy 0.74.0-0.4.hum1
    not affected: vulnerable code not present

Red Hat CSAF VEX © Red Hat, Inc., from https://security.access.redhat.com/data/csaf/v2/vex/; changed: reduced to product statuses and remediations. CC BY 4.0 · csaf

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
partial
Assessed
34 d ago

Exploit prediction

0.16% chance of exploitation in the next 30 days, higher than 5% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 4.0 5.9 CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:A/VC:N/VI:H/VA:N/SC:N/SI:L/SA:N
CNA 4.0 5.9 CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:A/VC:N/VI:H/VA:N/SC:N/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Affected products

  • moby BuildKit

Classification

Weakness
  • CWE-354 Improper Validation of Integrity Check Value

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.

CPEs and fixed versions use Anchore's correction of NVD's data: Added CPE configurations because not yet analyzed by NVD.