A vulnerability has been identified in WTV676-HB6035 Web Interface (All versions < V3.94), WTV776-HB6035 Web Interface (All versions < V4.1…
published 2026-09-16 54 d ago modified 2026-09-18 51 d ago also EUVD-2026-80250
- cvss
- 6.5
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.4%
- EPSS 0.4% chance of exploitation in 30 days, percentile 37%
- public exploits
- 0
- none known
Summary
A vulnerability has been identified in WTV676-HB6035 Web Interface (All versions < V3.94), WTV776-HB6035 Web Interface (All versions < V4.17). Affected devices do not properly validate input received from backend services. This could allow an unauthenticated remote attacker to force the device into protection mode, which results in losing remote connectivity functions (Web Access).
Patch / fix
- Siemens WTV676-HB6035 Web Interface V3.94
- Siemens WTV776-HB6035 Web Interface V4.17
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-26-265-08 updated cvss 6.5
Siemens WTV676 and WTV776
-
Siemens WTV676-HB6035 Web Interface < 3.94affected: fixed in V3.94 support.industry.siemens.com
-
Siemens WTV776-HB6035 Web Interface < 4.17affected: fixed in V4.17 support.industry.siemens.com
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- yes
- Technical impact
- partial
- Assessed
- 53 d ago
Exploit prediction
0.43% chance of exploitation in the next 30 days, higher than 37% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 6.5 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L |
| CNA | 4.0 | 6.9 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N |
| CNA | 4.0 | 6.9 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
Affected products
- Siemens WTV676-HB6035 Web Interface
- Siemens WTV776-HB6035 Web Interface
Classification
- Weakness
-
- CWE-1287 Improper Validation of Specified Type of Input