CVE-2026-76698 json
Authenticated Command Injection Vulnerability leads to Denial-of-Service in HPE Networking EdgeConnect SD-WAN Gateways
published 2026-09-15 54 d ago modified 2026-09-28 42 d ago also EUVD-2026-79224
- cvss
- 6.5
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 4.5%
- EPSS 4.5% chance of exploitation in 30 days, percentile 91%
- public exploits
- 0
- none known
Summary
A command injection vulnerability exists in the web-based management interface of HPE Networking EdgeConnect SD-WAN Gateways. An authenticated remote attacker with limited access privileges could exploit this vulnerability through specially crafted input. Successful exploitation, under certain conditions, could result in the execution of arbitrary commands with elevated privileges or a denial-of-service condition on the affected appliance.
Patch / fix
- arubanetworks edgeconnect_sd-wan_orchestrator 9.4.11, 9.5.9, 9.6.4
- hpe edgeconnect_operating_system 9.4.9.0, 9.5.9.0, 9.6.4.0
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- partial
- Assessed
- 48 d ago
Exploit prediction
4.53% chance of exploitation in the next 30 days, higher than 91% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 6.5 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H |
Affected products
- Hewlett Packard Enterprise (HPE) EdgeConnect SD-WAN Gateways
Classification
- Weakness
-
- CWE-77 Improper Neutralization of Special Elements used in a Command
References
Sources
- CVE List CVE-2026-76698
- NVD CVE-2026-76698
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.