Skip to content
Fencer Vulns
high 7.5

CVE-2026-76355 json

Unauthenticated Information Disclosure through an Edge Processor Service Endpoint in Splunk Enterprise

published 2026-08-19 2 mo ago modified 2026-08-26 2 mo ago also EUVD-2026-62920

cvss
7.5
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.5%
EPSS 0.5% chance of exploitation in 30 days, percentile 43%
public exploits
0
none known

Summary

In Splunk Enterprise 10.4 versions below 10.4.2, an unauthenticated user could retrieve the information contained in Edge Processor pipeline configurations through a Representational State Transfer (REST) API endpoint when Edge Processor is turned on. The vulnerability does not affect versions prior to 10.4. The vulnerability exists because the Edge Processor service endpoint lacks authentication controls. For more information see System architecture of the Edge Processor solution (https://help.splunk.com/en/splunk-enterprise/process-data-at-the-edge/use-edge-processors-for-splunk-enterprise/10.4/how-the-edge-processor-solution-works/system-architecture-of-the-edge-processor-solution) in the Splunk documentation.

Patch / fix

  • Splunk Splunk Enterprise 10.4.2

CISA SSVC

Exploitation
none
Automatable
yes
Technical impact
partial
Assessed
2 mo ago

Exploit prediction

0.50% chance of exploitation in the next 30 days, higher than 43% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 7.5 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Affected products

  • Splunk Splunk Enterprise

Classification

Weakness
  • CWE-306 Missing Authentication for Critical Functionality

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.