CVE-2026-73451 json
On affected platforms running Arista EOS with dual switch cards and with ingress Security ACLs configured on Switched Virtual Interfaces (SVI) in shared mode, restarting of the secondary switchcard forwarding agent or insertion of secondary switchcard, can
published 2026-09-15 54 d ago modified 2026-09-16 53 d ago also EUVD-2026-79140
- cvss
- 4.8
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.2%
- EPSS 0.2% chance of exploitation in 30 days, percentile 13%
- public exploits
- 0
- none known
Summary
On affected platforms running Arista EOS with dual switch cards and with ingress Security ACLs configured on Switched Virtual Interfaces (SVI) in shared mode, restarting of the secondary switchcard forwarding agent or insertion of secondary switchcard, can cause security ACLs on shared SVIs to stop functioning. This may result in incorrect packet permit/deny behavior.
This issue was discovered internally by Arista, and the company is not aware of any malicious exploitation of this vulnerability in customer networks.
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- partial
- Assessed
- 54 d ago
Exploit prediction
0.23% chance of exploitation in the next 30 days, higher than 13% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 4.8 | CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N |
| CNA | 4.0 | 6.3 | CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N |
| CNA | 4.0 | 6.3 | CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
Affected products
- Arista Networks EOS
Classification
- Weakness
-
- CWE-1419 Incorrect Initialization of Resource