Skip to content
Fencer Vulns
critical 9.8

CVE-2026-59178 json

ESPHome Device Builder: Renamed auth env vars silently disable dashboard authentication on upgrade

published 2026-09-14 55 d ago modified 2026-10-01 38 d ago also GHSA-rrxg-g2pf-6hh4 , PYSEC-2026-4049 , EUVD-2026-77758

cvss
9.8
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.8%
EPSS 0.8% chance of exploitation in 30 days, percentile 56%
public exploits
0
none known

Summary

ESPHome Device Builder Dashboard is a dashboard for the ESPHome home management software. Prior to version 1.0.12, the dashboard reads its authentication credentials from `$ESPHOME_USERNAME` and `$ESPHOME_PASSWORD`. Earlier versions, and the legacy `esphome` dashboard, read the bare `$USERNAME` and `$PASSWORD` instead. When the env vars were renamed the bare names were dropped with no fallback, so an operator who had protected their dashboard with `USERNAME` / `PASSWORD` (as the older getting started guide documented) loses authentication on upgrade and the dashboard starts open to anyone who can reach its port. The issue is fixed in 1.0.12. The bare `$USERNAME` / `$PASSWORD` are accepted again as a deprecated fallback so previously protected instances stay protected across the upgrade without operator intervention, with a loud deprecation warning at startup directing operators to rename them to `$ESPHOME_USERNAME` / `$ESPHOME_PASSWORD`. The fallback is gated on `$PASSWORD` being set and is only adopted as a pair, so the OS provided `$USERNAME` is never read on its own and the original collision footgun stays closed. A lone bare `$PASSWORD` with no username still fails loud as a credential mismatch rather than starting unauthenticated. This restores compatibility rather than failing closed on the legacy names, because the priority is that an instance which was protected before the upgrade stays protected without the operator having to act; the deprecation warning plus a future removal handles the migration. Operators should migrate to the `$ESPHOME_*` names. The esphome container delivers the fix in the 2026.6.2 release, which bumps its pinned `esphome-device-builder` version to 1.0.12. Without upgrading, restore authentication immediately by setting the new env vars to the same values, on any affected version. Alternatively, do not expose the dashboard port to untrusted networks, and check the startup logs for the `WITHOUT AUTHENTICATION` banner to confirm whether a given instance is currently open.

Patch / fix

CISA SSVC

Exploitation
none
Automatable
yes
Technical impact
total
Assessed
55 d ago

Exploit prediction

0.78% chance of exploitation in the next 30 days, higher than 56% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 9.8 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
OSV 3.1 9.8 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
GitHub 3.1 9.8 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Affected packages

ecosystem package affected fixed in
pypi esphome-device-builder
<1.0.12
1.0.12

Affected products

  • esphome device-builder

Classification

Weakness
  • CWE-306 Missing Authentication for Critical Functionality

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.