A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4-1 running Industrial OS with No…

published 2026-08-11 2 mo ago modified 2026-11-04 4 d ago also EUVD-2026-56119

cvss
10.0
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.9%
EPSS 0.9% chance of exploitation in 30 days, percentile 59%
public exploits
0
none known

Summary

A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed). Affected devices do not enforce authentication on the Node-RED HTTP interface, allowing unauthenticated access to programming nodes that are capable of executing system commands on the server. This could allow an unauthenticated remote attacker to create malicious flows through the HTTP interface in order to execute arbitrary code on the underlying server with maximum privileges.

Patch / fix

  • Siemens SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) V4.3.4-1
  • Siemens SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) V4.3.4-1
  • Siemens SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) V4.3.4-1
  • Siemens SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) V4.3.4-1

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-26-237-03 updated cvss 10.0

Siemens SIMATIC IoT2050 Advanced

Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf

CISA SSVC

Exploitation
none
Automatable
yes
Technical impact
total
Assessed
2 mo ago

Exploit prediction

0.89% chance of exploitation in the next 30 days, higher than 59% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 10.0 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
CNA 4.0 10.0 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
CNA 4.0 10.0 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Affected products

  • Siemens SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2)
  • Siemens SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2)
  • Siemens SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2)
  • Siemens SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2)

Classification

Weakness
  • CWE-306 Missing Authentication for Critical Functionality