Skip to content
Fencer Vulns
medium 6.5

CVE-2026-54704 json

OpenTelemetry Java Instrumentation: JDBC Auto-Instrumentation Logging Clear-Text Passwords

published 2026-07-01 4 mo ago modified 2026-10-25 14 d ago also EUVD-2026-41151 , GHSA-rwqx-fvqh-6wm4

cvss
6.5
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.4%
EPSS 0.4% chance of exploitation in 30 days, percentile 32%
public exploits
0
none known

Summary

OpenTelemetry Java Instrumentation provides OpenTelemetry auto-instrumentation and instrumentation libraries for Java. In versions prior to 2.28.0, the JDBC auto-instrumentation may fail to sanitize passwords in SQL CONNECT statements when the password is double-quoted. As a result, clear-text database passwords can be added to trace span attributes and exported to observability backends. This issue has been fixed in version 2.28.0.

Patch / fix

  • maven io.opentelemetry.javaagent:opentelemetry-javaagent 2.28.0-alpha
  • io.opentelemetry.javaagent opentelemetry-javaagent 2.28.0
  • linuxfoundation opentelemetry_instrumentation_for_java 2.28.0

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
partial
Assessed
4 mo ago

Exploit prediction

0.38% chance of exploitation in the next 30 days, higher than 32% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 6.5 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
GitHub 3.1 6.5 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

Affected packages

ecosystem package affected fixed in
maven io.opentelemetry.javaagent:opentelemetry-javaagent
<2.28.0-alpha
2.28.0-alpha

Affected products

  • open-telemetry opentelemetry-java-instrumentation

Classification

Weakness
  • CWE-532 Insertion of Sensitive Information into Log File

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.

CPEs and fixed versions use Anchore's correction of NVD's data: Added CPE configurations because not yet analyzed by NVD.