Skip to content
Fencer Vulns
high 7.8

CVE-2026-5397 json

Vulnerability Related to an Uncontrolled Search Path Element in a UPS Management Application

published 2026-04-15 6 mo ago modified 2026-10-25 14 d ago also EUVD-2026-22837

cvss
7.8
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.1%
EPSS 0.1% chance of exploitation in 30 days, percentile 2%
public exploits
0
none known

Summary

It has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power Supply) management application, whereby improper permissions on the installation directory allow a malicious actor to place a DLL that is then executed with administrator privileges.

If a malicious DLL is placed in the installation directory of this product, there is a possibility that the malicious DLL may be executed by exploiting the product’s behavior of loading missing DLLs from the same directory as the executable during service startup.

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
total
Assessed
6 mo ago

Exploit prediction

0.13% chance of exploitation in the next 30 days, higher than 2% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 7.8 CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H

Affected products

  • OMRON SOCIAL SOLUTIONS CO., Ltd. PowerAttendant Standard Edition

Classification

Weakness
  • CWE-427 Uncontrolled Search Path Element

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.