Skip to content
Fencer Vulns
high 7.5

CVE-2026-51601 json

Tenda CP3 V3.0 firmware V31.1.9.91 contains a stack-based buffer overflow in the RTSP service.

published 2026-07-09 4 mo ago modified 2026-07-10 3 mo ago also EUVD-2026-42644

cvss
7.5
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.6%
EPSS 0.6% chance of exploitation in 30 days, percentile 47%
public exploits
0
none known

Summary

Tenda CP3 V3.0 firmware V31.1.9.91 contains a stack-based buffer overflow in the RTSP service. The device fails to validate the length of the clock= value in the Range header field when processing a PLAY request. An unauthenticated remote attacker who has completed a standard RTSP session handshake can send a PLAY request with an excessively long clock= value to cause the RTSP service to crash.

CISA SSVC

Exploitation
none
Automatable
yes
Technical impact
partial
Assessed
3 mo ago

Exploit prediction

0.57% chance of exploitation in the next 30 days, higher than 47% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CISA ADP 3.1 7.5 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CNA 3.1 7.5 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Classification

Weakness
  • CWE-121 Stack-based Buffer Overflow

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.