CVE-2026-4827 json
Insufficient Entropy vulnerability on Multiple Products
published 2026-05-12 5 mo ago modified 2026-10-26 13 d ago also EUVD-2026-29459
- cvss
- 8.7
- version 4.0, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.3%
- EPSS 0.3% chance of exploitation in 30 days, percentile 24%
- public exploits
- 0
- none known
Summary
CWE‑331: Insufficient Entropy vulnerability exists that could lead to unauthorized access when an attacker on the network can exploit weaknesses in session‑management protections.
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-26-169-07 updated cvss 8.3
Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)
-
Schneider Electric Easergy C5 <= 1.1.17affected: vendor fix
-
Schneider Electric Easergy MiCOM C264 <= D7.33 Schneider Electric Easergy MiCOM C434 <= C434.679.700affected: vendor fix, mitigation
-
Schneider Electric Easergy MiCOM P40 Seriesaffected: mitigation
-
Schneider Electric Easergy MiCOM P138 <= P138.677.700 Schneider Electric Easergy MiCOM P139 <= P139.678.700affected: vendor fix, mitigation
-
Schneider Electric Easergy MiCOM P436 <= P436.677.701 Schneider Electric Easergy MiCOM P437 <= P437.678.700 Schneider Electric Easergy MiCOM P438 <= P438.677.701affected: mitigation
-
Schneider Electric Easergy MiCOM P439 <= P439.678.700affected: vendor fix, mitigation
-
Schneider Electric Easergy MiCOM P532 <= P532.678.700affected: mitigation
-
Schneider Electric Easergy MiCOM P539 <= P539.678.700affected: vendor fix, mitigation
show 7 moreshow fewer
-
Schneider Electric Easergy MiCOM P631 <= P631.678.700affected: mitigation
-
Schneider Electric Easergy MiCOM P632 <= P632.678.700 Schneider Electric Easergy MiCOM P633 <= P633.678.700, P633.680.700 Schneider Electric Easergy MiCOM P634 <= P634.678.700, P634.680.700affected: vendor fix, mitigation
-
Schneider Electric Easergy MiCOM P638 <= P638.677.700affected: mitigation
-
Schneider Electric EasyLogic T150 (formerly Saitel DR) EasyLogic T150 (formerly Saitel DR) <= 11.06.30 Schneider Electric EcoStruxure Power Automation System Gateway (EPAS-GTW) <= 6.4.616.200.100 Schneider Electric EcoStruxure Power Automation System User Interface (EPAS-UI) <= 3.0.3affected: vendor fix
-
Schneider Electric EcoStruxure Power Operation <= 2022_CU6, <= 2024_CU2affected: vendor fix community.se.com
-
Schneider Electric iPMFLS <= 64.2025.0.13 Schneider Electric PowerLogic P5 Protection Relay <= 02.502.103 Schneider Electric PowerLogic P7 Protection and Control Platform <= 02.002.002 Schneider Electric PowerLogic T300 <= 2.9.4 Schneider Electric PowerLogic T500 <= 11.08.02 Schneider Electric Saitel DP Saitel DP <= 11.06.36affected: vendor fix
-
Schneider Electric Easergy C5 1.1.18 Schneider Electric Easergy MiCOM C264 D7.34 Schneider Electric Easergy MiCOM C434 C434.679.700 Schneider Electric Easergy MiCOM P138 P138.677.701 Schneider Electric Easergy MiCOM P139 version P139.678.700 Schneider Electric Easergy MiCOM P439 P439.678.700fixed
+7 more productsfewer
Schneider Electric Easergy MiCOM P539 P539.678.700 Schneider Electric Easergy MiCOM P632 P632.678.700 Schneider Electric Easergy MiCOM P633 P633.680.701, P633.678.700 Schneider Electric Easergy MiCOM P634 P634.680.701 Schneider Electric EasyLogic T150 (formerly Saitel DR) Saitel DR 11.06.31 Schneider Electric EcoStruxure Power Automation Automation System User Interface (EPAS-UI) 3.0.4 Schneider Electric EcoStruxure Power Automation System Gateway (EPAS-GTW) 6.4.610.500.101
8 more fixed in the full advisory
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- yes
- Technical impact
- total
- Assessed
- 5 mo ago
Exploit prediction
0.31% chance of exploitation in the next 30 days, higher than 24% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 8.7 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N |
| CNA | 4.0 | 8.7 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
Affected products
- Schneider Electric Easergy MiCOM C264
- Schneider Electric Easergy C5
- Schneider Electric Easergy MiCOM P30
- Schneider Electric Easergy MiCOM P40
- Schneider Electric EcoStruxure™ Power Automation System Gateway (EPAS-GTW)
- Schneider Electric EcoStruxure™ Power Automation System User Interface (EPAS-UI)
- Schneider Electric EcoStruxure™ Power Operation
- Schneider Electric iPMFLS
- Schneider Electric PowerLogic™ P5 Protection Relay
- Schneider Electric PowerLogic™ P7 Protection and Control Platform
- Schneider Electric PowerLogic™ T300
- Schneider Electric PowerLogic™ T500
- Schneider Electric Saitel DP
- Schneider Electric EasyLogic T150 (formerly Saitel DR)
Classification
- Weakness
-
- CWE-331 Insufficient Entropy
References
Sources
- CVE List CVE-2026-4827
- NVD CVE-2026-4827