Skip to content
Fencer Vulns
high 8.8

CVE-2026-3556 json

Philips Hue Bridge HomeKit Pair-Setup Heap-based Buffer Overflow Remote Code Execution Vulnerability

published 2026-03-13 7 mo ago modified 2026-06-17 4 mo ago also EUVD-2026-12157

cvss
8.8
version 3.0, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.7%
EPSS 0.7% chance of exploitation in 30 days, percentile 53%
public exploits
0
none known

Summary

Philips Hue Bridge HomeKit Pair-Setup Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.

The specific flaw exists within the hk_hap_pair_storage_put function. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the HomeKit service. Was ZDI-CAN-28326.

Patch / fix

  • philips hue_bridge_v2_firmware 1975170000

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
total
Assessed
7 mo ago

Exploit prediction

0.69% chance of exploitation in the next 30 days, higher than 53% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.0 8.8 CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Affected products

  • Philips Hue Bridge

Classification

Weakness
  • CWE-122 Heap-based Buffer Overflow

References