CVE-2026-33893 json
A vulnerability has been identified in Teamcenter V2312 (All versions < V2312.0014), Teamcenter V2406 (All versions < V2406.0012), Teamcent…
published 2026-05-12 5 mo ago modified 2026-10-24 15 d ago also EUVD-2026-29432
- cvss
- 7.5
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.3%
- EPSS 0.3% chance of exploitation in 30 days, percentile 21%
- public exploits
- 0
- none known
Summary
A vulnerability has been identified in Teamcenter V2312 (All versions < V2312.0014), Teamcenter V2406 (All versions < V2406.0012), Teamcenter V2412 (All versions < V2412.0009), Teamcenter V2506 (All versions < V2506.0005), Teamcenter V2512 (All versions). The affected application contains hardcoded key which is used for obfuscation stored directly into the application. This could allow an attacker to obtain these keys and misuse them to gain unauthorized access.
Patch / fix
- Siemens Teamcenter V2312 V2312.0014
- Siemens Teamcenter V2406 V2406.0012
- Siemens Teamcenter V2412 V2412.0009
- Siemens Teamcenter V2506 V2506.0005
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-26-134-04 updated cvss 7.5
Siemens Teamcenter
-
Siemens Teamcenter V2312 < 2312.0014affected: fixed in V2312.0014 support.sw.siemens.com
-
Siemens Teamcenter V2406 < 2406.0012affected: fixed in V2406.0012 support.sw.siemens.com
-
Siemens Teamcenter V2412 < 2412.0009affected: fixed in V2412.0009 support.sw.siemens.com
-
Siemens Teamcenter V2506 < 2506.0005affected: fixed in V2506.0005 support.sw.siemens.com
-
Siemens Teamcenter V2512not affected: component not present
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- yes
- Technical impact
- partial
- Assessed
- 5 mo ago
Exploit prediction
0.29% chance of exploitation in the next 30 days, higher than 21% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 7.5 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N |
| CNA | 4.0 | 8.7 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N |
| CNA | 4.0 | 8.7 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
Affected products
- Siemens Teamcenter V2312
- Siemens Teamcenter V2406
- Siemens Teamcenter V2412
- Siemens Teamcenter V2506
- Siemens Teamcenter V2512
Classification
- Weakness
-
- CWE-798 Use of Hard-coded Credentials
References
-
cert-portal.siemens.com
/productcert/html/ssa-827383.html
vendor-advisory
Sources
- CVE List CVE-2026-33893
- NVD CVE-2026-33893
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.