Skip to content
Fencer Vulns
medium 6.5

CVE-2026-29771 json

Netmaker: Denial of Service via Server Shutdown Endpoint

published 2026-03-04 8 mo ago modified 2026-06-17 4 mo ago also EUVD-2026-10151 , GHSA-rhr9-hgcm-x289 , GO-2026-4608

cvss
6.5
version 3.1, NVD
cisa kev
Not listed
not in CISA's catalog
epss
0.4%
EPSS 0.4% chance of exploitation in 30 days, percentile 31%
public exploits
0
none known

Summary

Netmaker makes networks with WireGuard. Prior to version 1.2.0, the /api/server/shutdown endpoint allows termination of the Netmaker server process via syscall.SIGINT. This allows any user to repeatedly shut down the server, causing cyclic denial of service with approximately 3-second restart intervals. This issue has been patched in version 1.2.0.

Patch / fix

  • go github.com/gravitl/netmaker 1.2.0
  • gravitl netmaker 1.2.0
  • netmaker netmaker 1.2.0
  • govulncheck-vulndb openSUSE Leap 15.6 0.0.20260317T205859-150000.1.152.1

suse advisories SUSE-SU-2026:1042-1

  • govulncheck-vulndb openSUSE Leap 16.0 0.0.20260723T184607-160000.1.1

opensuse advisories openSUSE-SU-2026:21483-1

CISA SSVC

Exploitation
none
Automatable
yes
Technical impact
partial
Assessed
8 mo ago

Exploit prediction

0.37% chance of exploitation in the next 30 days, higher than 31% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 4.0 8.7 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
CNA 4.0 8.7 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
NVD 3.1 6.5 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

Affected packages

ecosystem package affected fixed in
go github.com/gravitl/netmaker
<1.2.0
1.2.0

Affected products

  • gravitl netmaker

Classification

Weakness
  • CWE-404 Improper Resource Shutdown or Release

References