Skip to content
Fencer Vulns
high 8.8

CVE-2026-18598 json

GL.iNet GL-MT3000 Logread Lua RPC plugin logread logread.get_system_log command injection

published 2026-08-03 3 mo ago modified 2026-10-23 16 d ago also EUVD-2026-52262

cvss
8.8
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
3.2%
EPSS 3.2% chance of exploitation in 30 days, percentile 88%
public exploits
0
none known

Summary

A vulnerability was detected in GL.iNet GL-MT3000 up to 4.4.5. The affected element is the function logread.get_system_log of the file /usr/lib/oui-httpd/rpc/logread of the component Logread Lua RPC plugin. The manipulation of the argument module results in command injection. The attack can be launched remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure and confirmed the existence of the vulnerability.

CISA SSVC

Exploitation
Proof of concept is public
Automatable
no
Technical impact
total
Assessed
3 mo ago

Exploit prediction

3.21% chance of exploitation in the next 30 days, higher than 88% of all scored CVEs (FIRST EPSS, 2026-11-08).

Exploits and checks

  • github.com https://github.com/StrTzz123/iot_vul/blob/main/GL-iNet/MT3000/4.4.5/logread_get_system_log_rpc_rce/CVE.md referenced PoC, tagged "exploit" by a source, unverified

CVSS scores

assigned by version score vector
CNA 4.0 8.7 CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
CNA 3.1 8.8 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
CNA 3.0 8.8 CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
CNA 2.0 9.0 AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:C
CNA 4.0 7.4 CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CNA 3.1 8.8 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CNA 2.0 9.0 AV:N/AC:L/Au:S/C:C/I:C/A:C

Affected products

  • GL.iNet GL-MT3000

Classification

Weakness
  • CWE-77 Improper Neutralization of Special Elements used in a Command
  • CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.