Skip to content
Fencer Vulns
high 8.8

CVE-2026-12562 json

Toptech Systems RCU II+ and Multiload II+ Missing Authentication for Critical Function

published 2026-07-30 3 mo ago modified 2026-09-08 2 mo ago also EUVD-2026-51329

cvss
8.8
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.5%
EPSS 0.5% chance of exploitation in 30 days, percentile 39%
public exploits
0
none known

Summary

The RCU II+ and Multiload II+ are vulnerable to an unauthenticated service that exposes a debug interface granting full root-level access to the embedded system. This vulnerability stems from a network-accessible port running a Target Communications Framework (TCF) service that does not require any authentication, allowing an attacker to directly interact with the Linux environment that powers the device. Once connected, an attacker can freely view and modify the filesystem, manipulate running processes, and control network interfaces, enabling deep alteration of system behavior.

Patch / fix

  • Toptech Systems RCU II+ 2025-11-24
  • Toptech Systems Multiload II+ 2025-11-24

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-26-211-03 updated cvss 8.8

Toptech Systems RCU II+ and Multiload II+

  • Toptech Systems Multiload II+ <2025-11-24 Toptech Systems RCU II+ <2025-11-24
    affected: mitigation “Toptech Systems provides two methods for remediating affected RCU II+ and Multiload II+ units: First, move the device to a closed or segmented network without untrusted access.” s3.amazonaws.com

From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
total
Assessed
3 mo ago

Exploit prediction

0.46% chance of exploitation in the next 30 days, higher than 39% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 8.8 CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CNA 4.0 8.7 CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CNA 4.0 8.7 CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Affected products

  • Toptech Systems RCU II+
  • Toptech Systems Multiload II+

Classification

Weakness
  • CWE-306 Missing Authentication for Critical Functionality

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.