CVE-2025-7932 json
D-Link DIR‑817L ssdpcgi lxmldbc_system command injection
published 2025-07-21 15 mo ago modified 2026-06-17 4 mo ago also EUVD-2025-22123
- cvss
- 6.3
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 5.9%
- EPSS 5.9% chance of exploitation in 30 days, percentile 93%
- public exploits
- 0
- none known
Summary
A vulnerability classified as critical has been found in D-Link DIR‑817L up to 1.04B01. This affects the function lxmldbc_system of the file ssdpcgi. The manipulation leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
Patch / fix
- dlink dir-817l_firmware 1.04b01
CISA SSVC
- Exploitation
- Proof of concept is public
- Automatable
- no
- Technical impact
- partial
- Assessed
- 15 mo ago
Exploit prediction
5.92% chance of exploitation in the next 30 days, higher than 93% of all scored CVEs (FIRST EPSS, 2026-11-08).
Exploits and checks
- github.com https://github.com/Patr1ck-S/Patr1ck-S.github.io/blob/main/D-Link%20DIR%E2%80%91817L%20has%20a%20remote%20arbitrary%20command%20execution%20vulnerability%20in%20ssdpcgi(1).md referenced PoC, tagged "exploit" by a source, unverified
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 5.3 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P |
| CNA | 3.1 | 6.3 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R |
| CNA | 3.0 | 6.3 | CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R |
| CNA | 2.0 | 6.5 | AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR |
| CNA | 4.0 | 2.1 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
| CNA | 3.1 | 6.3 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L |
| NVD | 3.1 | 8.8 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
| CNA | 2.0 | 6.5 | AV:N/AC:L/Au:S/C:P/I:P/A:P |
Affected products
- D-Link DIR‑817L
Classification
References
-
github.com
/Patr1ck-S/Patr1ck-S.github.io/blob/main/D-Link%20DIR%E2%80%91817L%20has%20a%20remote%20arbitrary%20command%20
exploit, third-party-advisory
-
vuldb.com
/?id.317061
vdb-entry, technical-description, third-party-advisory
-
vuldb.com
/?ctiid.317061
signature, permissions-required, vdb-entry
-
vuldb.com
/?submit.618951
third-party-advisory, vdb-entry
-
dlink.com
/
product
Sources
- CVE List CVE-2025-7932
- NVD CVE-2025-7932
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.