CVE-2025-7357 json
Plaintext Storage of a Password in LITEON IC48A and IC80A EV Chargers
published 2025-07-16 15 mo ago modified 2026-06-17 4 mo ago also EUVD-2025-21723
- cvss
- 8.7
- version 4.0, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.4%
- EPSS 0.4% chance of exploitation in 30 days, percentile 36%
- public exploits
- 0
- none known
Summary
LITEON IC48A firmware versions prior to 01.00.19r and LITEON IC80A firmware versions prior to 01.01.12e store FTP-server-access-credentials in cleartext in their system logs.
Patch / fix
- LITEON IC48A EV Charger 01.00.19r
- LITEON IC80A EV Charger 01.01.12e
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-25-196-03 updated cvss 7.5
LITEON IC48A and IC80A EV Chargers
-
LITEON IC48A <Firmware_01.00.19r LITEON IC80A <Firmware_01.01.12eaffected: vendor fix, mitigation “LITEON has released the following firmware versions for the following EV chargers:” liteon.com
From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- yes
- Technical impact
- partial
- Assessed
- 15 mo ago
Exploit prediction
0.42% chance of exploitation in the next 30 days, higher than 36% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 8.7 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N |
| CNA | 4.0 | 8.7 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
Affected products
- LITEON IC48A EV Charger
- LITEON IC80A EV Charger
Classification
- Weakness
-
- CWE-256 Plaintext Storage of a Password