CVE-2025-71284 json
Synway SMG Gateway Management Software OS Command Injection via radius_address
published 2026-04-30 6 mo ago modified 2026-10-07 33 d ago also EUVD-2025-209597
- cvss
- 9.8
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 5.7%
- EPSS 5.7% chance of exploitation in 30 days, percentile 93%
- public exploits
- 0
- none known
Summary
Synway SMG Gateway Management Software contains an OS command injection vulnerability in the RADIUS configuration endpoint at /en/9-2radius.php where the radius_address POST parameter is split and interpolated directly into a sed command without sanitization. An unauthenticated remote attacker can inject arbitrary shell commands by submitting a POST request with crafted radius_address, radius_address2, shared_secret2, source_ip, timeout, or retry parameters along with save=1 and enable_radius=1 to achieve remote code execution. Exploitation evidence was first observed by the Shadowserver Foundation on 2025-07-11 (UTC).
CISA SSVC
- Exploitation
- Proof of concept is public
- Automatable
- yes
- Technical impact
- total
- Assessed
- 6 mo ago
Exploit prediction
5.73% chance of exploitation in the next 30 days, higher than 93% of all scored CVEs (FIRST EPSS, 2026-11-08).
Exploits and checks
- mrxn.net https://mrxn.net/jswz/synway-9-2radius-rce.html referenced PoC, tagged "exploit" by a source, unverified
- mp.weixin.qq.com https://mp.weixin.qq.com/s/PyepoFSuQ63E3RnpQa9nsA referenced PoC, tagged "exploit" by a source, unverified
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 9.3 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N |
| CNA | 3.1 | 9.8 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| CNA | 4.0 | 9.3 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
Affected products
- Synway Information Engineering Co., Ltd. Synway SMG Gateway Management Software
Classification
- Weakness
-
- CWE-78 Improper Neutralization of Special Elements used in an OS Command
References
-
mrxn.net
/jswz/synway-9-2radius-rce.html
technical-description, exploit, third-party-advisory
-
mp.weixin.qq.com
/s/PyepoFSuQ63E3RnpQa9nsA
technical-description, exploit, third-party-advisory
-
github.com
/projectdiscovery/nuclei-templates/blob/main/http/vulnerabilities/synway/synwaysmg-radius-rce.yaml
third-party-advisory
-
synway.net
/
product
-
vulncheck.com
/advisories/synway-smg-gateway-management-software-os-command-injection-via-radius-address
third-party-advisory
Sources
- CVE List CVE-2025-71284
- NVD CVE-2025-71284
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.