CVE-2025-5965 in the critical feed json
RCE via the backup feature available only to user with high privilege
published 2026-01-05 10 mo ago modified 2026-10-07 32 d ago also EUVD-2026-0897
- cvss
- 7.2
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 28.2%
- EPSS 28.2% chance of exploitation in 30 days, percentile 98%
- public exploits
- 0
- none known
Summary
In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Backup configuration in the administration setup modules) allows OS Command Injection.This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.
Patch / fix
- Centreon Infra Monitoring 24.04.19, 24.10.15, 25.10.2
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- total
- Assessed
- 10 mo ago
Exploit prediction
28.23% chance of exploitation in the next 30 days, higher than 98% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 7.2 | CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H |
Affected products
- Centreon Infra Monitoring
Classification
- Weakness
-
- CWE-78 Improper Neutralization of Special Elements used in an OS Command
References
-
thewatch.centreon.com
/latest-security-bulletins-64/cve-2025-5965-centreon-web-high-severity-5362
vendor-advisory, patch
-
github.com
/centreon/centreon/releases
release-notes
Sources
- CVE List CVE-2025-5965
- NVD CVE-2025-5965
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.