Skip to content
Fencer Vulns
high 7.2

CVE-2025-5946 in the critical feed json

RCE via the poller reload feature available only to user with high privilege

published 2025-10-14 12 mo ago modified 2026-10-08 31 d ago also EUVD-2025-34208

cvss
7.2
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
13.5%
EPSS 13.5% chance of exploitation in 30 days, percentile 96%
public exploits
1
Metasploit

Summary

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Poller reload setup in the configuration modules) allows OS Command Injection. On the poller parameters page, a user with high privilege is able to concatenate custom instructions into the poller reload command.

This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.

Patch / fix

  • Centreon Infra Monitoring 23.10.28, 24.04.18, 24.10.13

Timeline

  1. First public exploit (Metasploit exploit/linux/http/centreon_auth_rce_cve_2025_5946)
  2. Published

CISA SSVC

Exploitation
none
Automatable
yes
Technical impact
total
Assessed
12 mo ago

Exploit prediction

13.51% chance of exploitation in the next 30 days, higher than 96% of all scored CVEs (FIRST EPSS, 2026-11-08).

Exploits and checks

CVSS scores

assigned by version score vector
CNA 3.1 7.2 CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Affected products

  • Centreon Infra Monitoring

Classification

Weakness
  • CWE-78 Improper Neutralization of Special Elements used in an OS Command

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.