CVE-2025-55705 json
EVMAPA Insufficient Session Expiration
published 2026-01-22 9 mo ago modified 2026-06-17 4 mo ago also EUVD-2026-4503
- cvss
- 7.3
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.3%
- EPSS 0.3% chance of exploitation in 30 days, percentile 26%
- public exploits
- 0
- none known
Summary
This vulnerability occurs when the system permits multiple simultaneous connections to the backend using the same charging station ID. This can result in unauthorized access, data inconsistency, or potential manipulation of charging sessions. The lack of proper session management and expiration control allows attackers to exploit this weakness by reusing valid charging station IDs to establish multiple sessions concurrently.
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-26-022-08 updated cvss 7.3
EVMAPA
-
EVMAPAaffected: vendor fix
From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- yes
- Technical impact
- partial
- Assessed
- 9 mo ago
Exploit prediction
0.33% chance of exploitation in the next 30 days, higher than 26% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 7.3 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L |
| NVD | 3.1 | 9.8 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
Affected products
- EVMAPA EVMAPA
Classification
- Weakness
-
- CWE-613 DEPRECATED: Insufficient Session Expiration
References
-
cisa.gov
/news-events/ics-advisories/icsa-26-022-08
third-party-advisory, us-government-resource
-
github.com
/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-022-08.json
third-party-advisory
Sources
- CVE List CVE-2025-55705
- NVD CVE-2025-55705
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.
CPEs and fixed versions use Anchore's correction of NVD's data: Added CPE configurations because not yet analyzed by NVD.