CVE-2025-54924 json
CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker se…
published 2025-08-20 14 mo ago modified 2026-06-17 4 mo ago also EUVD-2025-25292
- cvss
- 7.5
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.5%
- EPSS 0.5% chance of exploitation in 30 days, percentile 39%
- public exploits
- 0
- none known
Summary
CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker sends a specially crafted document to a vulnerable endpoint.
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-25-224-03 updated cvss 7.5
Schneider Electric EcoStruxure Power Monitoring Expert
-
Schneider Electric EcoStruxure Power Monitoring Expert (PME) 2022, 2023, 2024, 2024_R2 Schneider Electric EcoStruxure Power Monitoring Expert (PME) 2023 CSAFPID-0012 Schneider Electric EcoStruxure Power Monitoring Expert (PME) 2023_R2 CSAFPID-0012 Schneider Electric EcoStruxure Power Monitoring Expert (PME) 2024 CSAFPID-0012, CSAFPID-0013 Schneider Electric EcoStruxure Power Monitoring Expert (PME) 2024_R2 CSAFPID-0012, CSAFPID-0013affected: vendor fix, mitigation product-help.schneider-electric.com
-
Schneider Electric EcoStruxure Power Monitoring Expert (PME) 2023_R2_Hotfix_199767, 2023_R2_Hotfix_273686_.12.0, Hotfix_279338_Release_2024R2fixed
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- yes
- Technical impact
- partial
- Assessed
- 14 mo ago
Exploit prediction
0.45% chance of exploitation in the next 30 days, higher than 39% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 7.5 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N |
Affected products
- Schneider Electric EcoStruxure™ Power Monitoring Expert (PME)
- Schneider Electric EcoStruxure™ Power Operation (EPO) Advanced Reporting and Dashboards Module
Classification
- Weakness
-
- CWE-918 Server-Side Request Forgery
References
Sources
- CVE List CVE-2025-54924
- NVD CVE-2025-54924
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.