Summary

Prior to September 19, 2025, the Hospital Manager Backend Services exposed the ASP.NET tracing endpoint /trace.axd without authentication, allowing a remote attacker to obtain live request traces and sensitive information such as request metadata, session identifiers, authorization headers, server variables, and internal file paths.

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSMA-25-301-01 updated cvss 7.5

Vertikal Systems Hospital Manager Backend Services

  • Vertikal Systems Hospital Manager Backend Services <=September_19_2025
    affected: mitigation “Vertikal Systems fixed these vulnerabilities by September 19, 2025. For more information, users should contact Vertikal Systems support for assistance.” vertikalsystems.com

From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
partial
Assessed
12 mo ago

Exploit prediction

0.42% chance of exploitation in the next 30 days, higher than 36% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 4.0 8.7 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
CNA 3.1 7.5 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
CNA 4.0 8.7 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Affected products

  • Vertikal Systems Hospital Manager Backend Services

Classification

Weakness
  • CWE-497 Exposure of Sensitive System Information to an Unauthorized Control Sphere