CVE-2025-5443 json
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 wirelessAdvancedHidden os command injection
published 2025-06-02 17 mo ago modified 2026-06-17 4 mo ago also EUVD-2025-16649
- cvss
- 6.3
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 13.6%
- EPSS 13.6% chance of exploitation in 30 days, percentile 96%
- public exploits
- 0
- none known
Summary
A vulnerability, which was classified as critical, was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected is the function wirelessAdvancedHidden of the file /goform/wirelessAdvancedHidden. The manipulation of the argument ExtChSelector/24GSelector/5GSelector leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CISA SSVC
- Exploitation
- Proof of concept is public
- Automatable
- no
- Technical impact
- partial
- Assessed
- 17 mo ago
Exploit prediction
13.56% chance of exploitation in the next 30 days, higher than 96% of all scored CVEs (FIRST EPSS, 2026-11-08).
Exploits and checks
- github.com https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_6/6.md referenced PoC, tagged "exploit" by a source, unverified
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 5.3 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N |
| CNA | 3.1 | 6.3 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L |
| CNA | 3.0 | 6.3 | CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L |
| CNA | 2.0 | 6.5 | AV:N/AC:L/Au:S/C:P/I:P/A:P |
| CNA | 4.0 | 5.3 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
| NVD | 3.1 | 9.8 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
Affected products
- Linksys RE6500
- Linksys RE6250
- Linksys RE6300
- Linksys RE6350
- Linksys RE7000
- Linksys RE9000
Classification
References
-
github.com
/wudipjq/my_vuln/blob/main/Linksys/vuln_6/6.md
exploit, third-party-advisory
-
vuldb.com
/?id.310782
vdb-entry, technical-description, third-party-advisory
-
vuldb.com
/?ctiid.310782
signature, permissions-required
-
vuldb.com
/?submit.584365
third-party-advisory, vdb-entry
-
linksys.com
/
product
Sources
- CVE List CVE-2025-5443
- NVD CVE-2025-5443
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.