CVE-2025-48819 json
Windows Universal Plug and Play (UPnP) Device Host Elevation of Privilege Vulnerability
published 2025-07-08 16 mo ago modified 2026-06-17 4 mo ago also EUVD-2025-20588
- cvss
- 7.1
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.4%
- EPSS 0.4% chance of exploitation in 30 days, percentile 33%
- public exploits
- 0
- none known
Summary
Sensitive data storage in improperly locked memory in Windows Universal Plug and Play (UPnP) Device Host allows an authorized attacker to elevate privileges over an adjacent network.
Patch / fix
- Microsoft Windows 10 Version 1507 10.0.10240.21073
- Microsoft Windows 10 Version 1607 10.0.14393.8246
- Microsoft Windows 10 Version 1809 10.0.17763.7558
- Microsoft Windows 10 Version 21H2 10.0.19044.6093
- Microsoft Windows 10 Version 22H2 10.0.19045.6093
- Microsoft Windows 11 version 22H2 10.0.22621.5624
- Microsoft Windows 11 version 22H3 10.0.22631.5624
- Microsoft Windows 11 Version 23H2 10.0.22631.5624
- Microsoft Windows 11 Version 24H2 10.0.26100.4652
- Microsoft Windows Server 2008 R2 Service Pack 1 6.1.7601.27820
- Microsoft Windows Server 2008 R2 Service Pack 1 (Server Core installation) 6.1.7601.27820
- Microsoft Windows Server 2008 Service Pack 2 6.0.6003.23418
- Microsoft Windows Server 2008 Service Pack 2 (Server Core installation) 6.0.6003.23418
- Microsoft Windows Server 2012 6.2.9200.25573
- Microsoft Windows Server 2012 (Server Core installation) 6.2.9200.25573
- Microsoft Windows Server 2012 R2 6.3.9600.22676
- Microsoft Windows Server 2012 R2 (Server Core installation) 6.3.9600.22676
- Microsoft Windows Server 2016 10.0.14393.8246
- Microsoft Windows Server 2016 (Server Core installation) 10.0.14393.8246
- Microsoft Windows Server 2019 10.0.17763.7558
- Microsoft Windows Server 2019 (Server Core installation) 10.0.17763.7558
- Microsoft Windows Server 2022 10.0.20348.3932
- Microsoft Windows Server 2022, 23H2 Edition (Server Core installation) 10.0.25398.1732
- Microsoft Windows Server 2025 10.0.26100.4652
- Microsoft Windows Server 2025 (Server Core installation) 10.0.26100.4652
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- total
- Assessed
- 16 mo ago
Exploit prediction
0.39% chance of exploitation in the next 30 days, higher than 33% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 7.1 | CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C |
| CNA | 3.1 | 7.1 | CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H |
Affected products
- Microsoft Windows 10 Version 1507
- Microsoft Windows 10 Version 1607
- Microsoft Windows 10 Version 1809
- Microsoft Windows 10 Version 21H2
- Microsoft Windows 10 Version 22H2
- Microsoft Windows 11 version 22H2
- Microsoft Windows 11 version 22H3
- Microsoft Windows 11 Version 23H2
- Microsoft Windows 11 Version 24H2
- Microsoft Windows Server 2008 R2 Service Pack 1
- Microsoft Windows Server 2008 R2 Service Pack 1 (Server Core installation)
- Microsoft Windows Server 2008 Service Pack 2
- Microsoft Windows Server 2008 Service Pack 2 (Server Core installation)
- Microsoft Windows Server 2012
- Microsoft Windows Server 2012 (Server Core installation)
- Microsoft Windows Server 2012 R2
- Microsoft Windows Server 2012 R2 (Server Core installation)
- Microsoft Windows Server 2016
- Microsoft Windows Server 2016 (Server Core installation)
- Microsoft Windows Server 2019
- Microsoft Windows Server 2019 (Server Core installation)
- Microsoft Windows Server 2022
- Microsoft Windows Server 2022, 23H2 Edition (Server Core installation)
- Microsoft Windows Server 2025
- Microsoft Windows Server 2025 (Server Core installation)
Classification
- Weakness
-
- CWE-591 Sensitive Data Storage in Improperly Locked Memory
References
-
msrc.microsoft.com
/update-guide/vulnerability/CVE-2025-48819
vendor-advisory, patch
Sources
- CVE List CVE-2025-48819
- NVD CVE-2025-48819
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.