Skip to content
Fencer Vulns
medium 6.2

CVE-2025-48415 json

Backdoor Functionality via USB Drive in eCharge Hardy Barth cPH2 / cPP2 charging stations

published 2025-05-21 17 mo ago modified 2026-06-17 4 mo ago also EUVD-2025-16010

cvss
6.2
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.2%
EPSS 0.2% chance of exploitation in 30 days, percentile 12%
public exploits
0
none known

Summary

A USB backdoor feature can be triggered by attaching a USB drive that contains specially crafted "salia.ini" files. The .ini file can contain several "commands" that could be exploited by an attacker to export or modify the device configuration, enable an SSH backdoor  or perform other administrative actions. Ultimately, this backdoor also allows arbitrary execution of OS commands.

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
partial
Assessed
17 mo ago

Exploit prediction

0.22% chance of exploitation in the next 30 days, higher than 12% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CISA ADP 3.1 6.2 CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
CNA 3.1 6.2 CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N

Affected products

  • eCharge Hardy Barth cPH2 / cPP2 charging stations

Classification

Weakness
  • CWE-749 Exposed Dangerous Method or Function

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.