Skip to content
Fencer Vulns
high 7.4

CVE-2025-40800 json

A vulnerability has been identified in COMOS V10.6 (All versions < V10.6.1), COMOS V10.6 (All versions < V10.6.1), NX V2412 (All versions <…

published 2025-12-09 11 mo ago modified 2026-10-07 33 d ago also EUVD-2025-201929

cvss
7.4
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.2%
EPSS 0.2% chance of exploitation in 30 days, percentile 10%
public exploits
0
none known

Summary

A vulnerability has been identified in COMOS V10.6 (All versions < V10.6.1), COMOS V10.6 (All versions < V10.6.1), NX V2412 (All versions < V2412.8700), NX V2506 (All versions < V2506.6000), Simcenter 3D (All versions < V2506.6000), Simcenter Femap (All versions < V2506.0002), Solid Edge SE2025 (All versions < V225.0 Update 10), Solid Edge SE2026 (All versions < V226.0 Update 1). The IAM client in affected products is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack.

Patch / fix

  • Siemens COMOS V10.6 V10.6.1
  • Siemens NX V2412 V2412.8700
  • Siemens NX V2506 V2506.6000
  • Siemens Simcenter 3D V2506.6000
  • Siemens Simcenter Femap V2506.0002
  • Siemens Solid Edge SE2025 V225.0 Update 10
  • Siemens Solid Edge SE2026 V226.0 Update 1

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-25-345-04 updated cvss 7.4

Siemens IAM Client

Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf

cisa ICSA-26-043-03 updated cvss 7.4

Siemens COMOS

Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
total
Assessed
11 mo ago

Exploit prediction

0.21% chance of exploitation in the next 30 days, higher than 10% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 7.4 CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N
CNA 4.0 9.1 CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N
CNA 4.0 9.1 CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Affected products

  • Siemens COMOS V10.6
  • Siemens NX V2412
  • Siemens NX V2506
  • Siemens Simcenter 3D
  • Siemens Simcenter Femap
  • Siemens Solid Edge SE2025
  • Siemens Solid Edge SE2026

Classification

Weakness
  • CWE-295 Improper Certificate Validation

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.