CVE-2025-40594 json
A vulnerability has been identified in SINAMICS G220 V6.4 (All versions < V6.4 HF2), SINAMICS S200 V6.4 (All versions < V6.4 HF7), SINAMICS…
published 2025-09-09 14 mo ago modified 2026-10-23 16 d ago also EUVD-2025-27242
- cvss
- 6.3
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.2%
- EPSS 0.2% chance of exploitation in 30 days, percentile 11%
- public exploits
- 0
- none known
Summary
A vulnerability has been identified in SINAMICS G220 V6.4 (All versions < V6.4 HF2), SINAMICS S200 V6.4 (All versions < V6.4 HF7), SINAMICS S210 V6.4 (All versions < V6.4 HF2). The affected devices allow a factory reset to be executed without the required privileges due to improper privilege management as well as manipulation of configuration data because of leaked privileges of previous sessions. This could allow an unauthorized attacker to escalate their privileges.
Patch / fix
- Siemens SINAMICS G220 V6.4 V6.4 HF2
- Siemens SINAMICS S200 V6.4 V6.4 HF7
- Siemens SINAMICS S210 V6.4 V6.4 HF2
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-25-254-03 updated cvss 6.3
Siemens SINAMICS Drives
-
Siemens SINAMICS G220 V6.4 <V6.4_HF2affected: fixed in V6.4 support.industry.siemens.com
-
Siemens SINAMICS S200 V6.4 <V6.4_HF7affected: fixed in V6.4 support.industry.siemens.com
-
Siemens SINAMICS S210 V6.4 <V6.4_HF2affected: fixed in V6.4 support.industry.siemens.com
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- partial
- Assessed
- 13 mo ago
Exploit prediction
0.21% chance of exploitation in the next 30 days, higher than 11% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 6.3 | CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:C/C:N/I:H/A:L |
| CNA | 4.0 | 6.9 | CVSS:4.0/AV:L/AC:H/AT:P/PR:N/UI:A/VC:N/VI:H/VA:L/SC:N/SI:H/SA:L |
| CNA | 4.0 | 6.9 | CVSS:4.0/AV:L/AC:H/AT:P/PR:N/UI:A/VC:N/VI:H/VA:L/SC:N/SI:H/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
| NVD | 3.1 | 9.8 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
Affected products
- Siemens SINAMICS G220 V6.4
- Siemens SINAMICS S200 V6.4
- Siemens SINAMICS S210 V6.4
Classification
- Weakness
-
- CWE-269 Improper Privilege Management
References
-
cert-portal.siemens.com
/productcert/html/ssa-027652.html
vendor-advisory
Sources
- CVE List CVE-2025-40594
- NVD CVE-2025-40594
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.