CVE-2025-35034 json
Medical Informatics Engineering Enterprise Health reflected cross site scripting via portlet_user_id
published 2025-09-29 13 mo ago modified 2026-10-09 31 d ago also EUVD-2025-31612
- cvss
- 4.3
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.3%
- EPSS 0.3% chance of exploitation in 30 days, percentile 17%
- public exploits
- 0
- none known
Summary
Medical Informatics Engineering Enterprise Health has a reflected cross site scripting vulnerability in the 'portlet_user_id' URL parameter. A remote, unauthenticated attacker can craft a URL that can execute arbitrary JavaScript in the victim's browser. This issue is fixed as of 2025-03-14.
Patch / fix
- Medical Informatics Engineering Enterprise Health RC202309 2025-04-08, RC202403 2025-04-08, RC202409 2025-04-08, RC202503 2025-04-08
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa vex VA-25-272-01 updated cvss 4.3
Medical Informatics Engineering Enterprise Health multiple vulnerabilities
-
Medical Informatics Engineering Enterprise Health >=RC202503, <RC202503 2025-04-08, >=RC202409, <RC202409 2025-04-08, >=RC202403, <RC202403 2025-04-08, >=RC202309, <RC202309 2025-04-08affected: vendor fix
-
Medical Informatics Engineering Enterprise Health RC202503 2025-04-08, RC202409 2025-04-08, RC202403 2025-04-08, RC202309 2025-04-08fixed: vendor fix
From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- partial
- Assessed
- 13 mo ago
Exploit prediction
0.26% chance of exploitation in the next 30 days, higher than 17% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 4.3 | CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N |
| CNA | 4.0 | 5.1 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N |
| CNA | 4.0 | 5.1 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
| NVD | 3.1 | 6.1 | CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N |
Affected products
- Medical Informatics Engineering Enterprise Health
Classification
- Weakness
-
- CWE-79 Improper Neutralization of Input During Web Page Generation
References
-
raw.githubusercontent.com
/cisagov/CSAF/develop/csaf_files/IT/white/2025/va-25-272-01.json
third-party-advisory
-
cve.org
/CVERecord?id=CVE-2025-35034
third-party-advisory, us-government-resource
Sources
- CVE List CVE-2025-35034
- NVD CVE-2025-35034
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.