Skip to content
Fencer Vulns
critical 9.9

CVE-2025-3498 json

Unauthenticated modification of Radiflow iSAP Smart Collector configuration

published 2025-07-09 16 mo ago modified 2026-06-17 4 mo ago also EUVD-2025-20795

cvss
9.9
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.3%
EPSS 0.3% chance of exploitation in 30 days, percentile 28%
public exploits
0
none known

Summary

An unauthenticated user with management network access can get and modify the Radiflow iSAP Smart Collector (CentOS 7 - VSAP 1.20) configuration. The device has two web servers that expose unauthenticated REST APIs on the management network (TCP ports 8084 and 8086). An attacker can use these APIs to get access to all system settings, modify the configuration and execute some commands (e.g., system reboot).

Patch / fix

  • Radiflow iSAP Smart Collector 3.02-1

CISA SSVC

Exploitation
none
Automatable
yes
Technical impact
partial
Assessed
16 mo ago

Exploit prediction

0.35% chance of exploitation in the next 30 days, higher than 28% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 9.9 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:L

Affected products

  • Radiflow iSAP Smart Collector

Classification

Weakness
  • CWE-306 Missing Authentication for Critical Functionality

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.