Skip to content
Fencer Vulns
medium 5.8

CVE-2025-34229 json

Vasion Print (formerly PrinterLogic) Blind SSRF via HP installApp.php

published 2025-09-29 13 mo ago modified 2026-10-18 21 d ago also EUVD-2025-31630

cvss
5.8
version 3.1, NVD
cisa kev
Not listed
not in CISA's catalog
epss
0.5%
EPSS 0.5% chance of exploitation in 30 days, percentile 45%
public exploits
0
none known

Summary

Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 25.1.102 and Application prior to version 25.1.1413 (VA/SaaS deployments) contain a blind server-side request forgery (SSRF) vulnerability reachable via the /var/www/app/console_release/hp/installApp.php script that can be exploited by an unauthenticated user. When a printer is registered, the software stores the printer’s host name in the variable $printer_vo->str_host_address. The code later builds a URL like 'http://<host‑address>:80/DevMgmt/DiscoveryTree.xml' and sends the request with curl. No validation, whitelist, or private‑network filtering is performed before the request is made. Because the request is blind, an attacker cannot see the data directly, but can still: probe internal services, trigger internal actions, or gather other intelligence. This vulnerability has been confirmed to be remediated, but it is unclear as to when the patch was introduced.

Patch / fix

  • Vasion Print Virtual Appliance Host 25.1.102
  • Vasion Print Application 25.1.1413

CISA SSVC

Exploitation
Proof of concept is public
Automatable
yes
Technical impact
partial
Assessed
13 mo ago

Exploit prediction

0.53% chance of exploitation in the next 30 days, higher than 45% of all scored CVEs (FIRST EPSS, 2026-11-08).

Exploits and checks

  • pierrekim.github.io https://pierrekim.github.io/blog/2025-04-08-vasion-printerlogic-83-vulnerabilities.html#va-ssrf-05 referenced PoC, tagged "exploit" by a source, unverified

CVSS scores

assigned by version score vector
CNA 4.0 6.9 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N
CNA 4.0 6.9 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
NVD 3.1 5.8 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N

Affected products

  • Vasion Print Virtual Appliance Host
  • Vasion Print Application

Classification

Weakness
  • CWE-306 Missing Authentication for Critical Functionality
  • CWE-918 Server-Side Request Forgery

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.