CVE-2025-32868 json
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2).
published 2025-04-16 18 mo ago modified 2026-06-17 4 mo ago also EUVD-2025-11399
- cvss
- 8.8
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.5%
- EPSS 0.5% chance of exploitation in 30 days, percentile 39%
- public exploits
- 0
- none known
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ExportCertificate' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Patch / fix
- Siemens TeleControl Server Basic V3.1.2.2
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-25-112-01 updated cvss 8.8
Siemens TeleControl Server Basic SQL
-
Siemens TeleControl Server Basic <V3.1.2.2affected: fixed in V3.1.2.2, mitigation support.industry.siemens.com
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- total
- Assessed
- 18 mo ago
Exploit prediction
0.46% chance of exploitation in the next 30 days, higher than 39% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 8.8 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
| CNA | 4.0 | 8.7 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N |
| CNA | 4.0 | 8.7 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
Affected products
- Siemens TeleControl Server Basic
Classification
- Weakness
-
- CWE-89 Improper Neutralization of Special Elements used in an SQL Command
References
-
cert-portal.siemens.com
/productcert/html/ssa-443402.html
vendor-advisory
Sources
- CVE List CVE-2025-32868
- NVD CVE-2025-32868