Skip to content
Fencer Vulns
high 7.8

CVE-2025-32454 json

A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.14), Teamcenter Visualization V2312 (All vers…

published 2025-05-13 17 mo ago modified 2026-06-17 4 mo ago also EUVD-2025-14708

cvss
7.8
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.2%
EPSS 0.2% chance of exploitation in 30 days, percentile 7%
public exploits
0
none known

Summary

A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.14), Teamcenter Visualization V2312 (All versions < V2312.0010), Teamcenter Visualization V2406 (All versions < V2406.0008), Teamcenter Visualization V2412 (All versions < V2412.0004), Tecnomatix Plant Simulation V2404 (All versions < V2404.0013). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.

Patch / fix

  • Siemens Teamcenter Visualization V14.3 V14.3.0.14
  • Siemens Teamcenter Visualization V2312 V2312.0010
  • Siemens Teamcenter Visualization V2406 V2406.0008
  • Siemens Teamcenter Visualization V2412 V2412.0004
  • Siemens Tecnomatix Plant Simulation V2404 V2404.0013

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-25-162-01 updated cvss 7.8

Siemens Tecnomatix Plant Simulation

  • Siemens Tecnomatix Plant Simulation V2404 < V2404.0013
    affected: fixed in V2404.0013, mitigation support.sw.siemens.com

Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf

cisa ICSA-25-135-06 updated cvss 7.8

Siemens Teamcenter Visualization

  • Siemens Teamcenter Visualization V14.3 < V14.3.0.14
    affected: fixed in V14.3.0.14, mitigation support.sw.siemens.com
  • Siemens Teamcenter Visualization V2312 < V2312.0010
    affected: fixed in V2312.0010, mitigation support.sw.siemens.com
  • Siemens Teamcenter Visualization V2406 < V2406.0008
    affected: fixed in V2406.0008, mitigation support.sw.siemens.com
  • Siemens Teamcenter Visualization V2412 < V2412.0004
    affected: fixed in V2412.0004, mitigation support.sw.siemens.com

Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
total
Assessed
17 mo ago

Exploit prediction

0.18% chance of exploitation in the next 30 days, higher than 7% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 7.8 CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
CNA 4.0 7.3 CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CNA 4.0 7.3 CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Affected products

  • Siemens Teamcenter Visualization V14.3
  • Siemens Teamcenter Visualization V2312
  • Siemens Teamcenter Visualization V2406
  • Siemens Teamcenter Visualization V2412
  • Siemens Tecnomatix Plant Simulation V2404

Classification

Weakness

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.