Skip to content
Fencer Vulns
high 7.2

CVE-2025-30199 json

ECOVACS Vacuum and Base Station accept unsigned firmware

published 2025-09-05 14 mo ago modified 2026-10-18 21 d ago also EUVD-2025-27021

cvss
7.2
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.3%
EPSS 0.3% chance of exploitation in 30 days, percentile 22%
public exploits
0
none known

Summary

ECOVACS vacuum robot base stations do not validate firmware updates, so malicious over-the-air updates can be sent to base station via insecure connection between robot and base station.

Patch / fix

  • ecovacs deebot_x1s_pro_firmware 2.4.45, 2.5.38
  • ecovacs deebot_x1_pro_omni_firmware 2.5.38
  • ecovacs deebot_x1_omni_firmware 2.4.45
  • ecovacs deebot_x1_turbo_firmware 2.5.38
  • ecovacs deebot_t10_firmware 1.11.0
  • ecovacs deebot_t10_omni_firmware 1.11.0
  • ecovacs deebot_t10_plus_firmware 1.11.0
  • ecovacs deebot_t10_turbo_firmware 1.11.0
  • ecovacs deebot_t20_omni_firmware 1.25.0
  • ecovacs deebot_t20_pro_plus_firmware 1.25.0
  • ecovacs deebot_t20_pro_firmware 1.25.0
  • ecovacs deebot_t30_omni_firmware 1.100.0
  • ecovacs deebot_t30s_firmware 1.100.0

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-25-135-19 updated cvss 7.2

ECOVACS DEEBOT Vacuum and Base Station (Update A)

  • ECOVACS T10 Series <1.11.0 ECOVACS T20 Series <1.25.0 ECOVACS T30 Series <1.100.0 ECOVACS X1 OMNI <2.4.45 ECOVACS X1 PRO OMNI <2.5.38 ECOVACS X1 TURBO <2.4.45
    +1 more products
    ECOVACS X1S PRO <2.5.38
    affected: mitigation “For more information, see ECOVACS security advisory.” ecovacs.com

From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
total
Assessed
14 mo ago

Exploit prediction

0.30% chance of exploitation in the next 30 days, higher than 22% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 7.2 CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
CNA 4.0 7.5 CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CNA 4.0 7.5 CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Affected products

  • ECOVACS DEEBOT X1 Series
  • ECOVACS DEEBOT T20 Series
  • ECOVACS DEEBOT T10 Series
  • ECOVACS DEEBOT T30 Series

Classification

Weakness
  • CWE-494 Download of Code Without Integrity Check

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.