CVE-2025-30174 json
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions <…
published 2025-05-13 17 mo ago modified 2026-06-17 4 mo ago also EUVD-2025-14391
- cvss
- 7.5
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.7%
- EPSS 0.7% chance of exploitation in 30 days, percentile 51%
- public exploits
- 0
- none known
Summary
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions < V2.15.1.1). Affected products contain a out of bound read buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.
Patch / fix
- Siemens SINEC NMS V4.0
- Siemens User Management Component (UMC) V2.15.1.1
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-25-135-09 updated cvss 7.5
Siemens User Management Component (UMC)
-
Siemens SIMATIC PCS neo V4.1 Siemens SIMATIC PCS neo V5.0affected: mitigation, no fix planned
-
Siemens SINEC NMS < 4.0affected: fixed in V4.0, mitigation support.industry.siemens.com
-
Siemens SINEMA Remote Connect Siemens Totally Integrated Automation Portal (TIA Portal) V17 Siemens Totally Integrated Automation Portal (TIA Portal) V18 Siemens Totally Integrated Automation Portal (TIA Portal) V19 Siemens Totally Integrated Automation Portal (TIA Portal) V20affected: fixed in V2.15.1.1, mitigation
-
Siemens User Management Component (UMC) < 2.15.1.1affected: fixed in V2.15.1.1, mitigation support.industry.siemens.com
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- yes
- Technical impact
- partial
- Assessed
- 17 mo ago
Exploit prediction
0.65% chance of exploitation in the next 30 days, higher than 51% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 7.5 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H |
| CNA | 4.0 | 8.7 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N |
| CNA | 4.0 | 8.7 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
Affected products
- Siemens SIMATIC PCS neo V4.1
- Siemens SIMATIC PCS neo V5.0
- Siemens SINEC NMS
- Siemens SINEMA Remote Connect
- Siemens Totally Integrated Automation Portal (TIA Portal) V17
- Siemens Totally Integrated Automation Portal (TIA Portal) V18
- Siemens Totally Integrated Automation Portal (TIA Portal) V19
- Siemens Totally Integrated Automation Portal (TIA Portal) V20
- Siemens User Management Component (UMC)
Classification
- Weakness
-
- CWE-125 Out-of-bounds Read
References
-
cert-portal.siemens.com
/productcert/html/ssa-614723.html
vendor-advisory
Sources
- CVE List CVE-2025-30174
- NVD CVE-2025-30174
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.