Skip to content
Fencer Vulns
medium 6.3

CVE-2025-26620 json

Duende.AccessTokenManagement race condition when concurrently retrieving customized Client Credentials Access Tokens

published 2025-02-18 20 mo ago modified 2026-06-17 4 mo ago also GHSA-qxj7-2x7w-3mpp , EUVD-2025-4683

cvss
6.3
version 4.0, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.4%
EPSS 0.4% chance of exploitation in 30 days, percentile 33%
public exploits
0
none known

Summary

Duende.AccessTokenManagement is a set of .NET libraries that manage OAuth and OpenId Connect access tokens. Duende.AccessTokenManagement contains a race condition when requesting access tokens using the client credentials flow. Concurrent requests to obtain an access token using differing protocol parameters can return access tokens obtained with the wrong scope, resource indicator, or other protocol parameters. Such usage is somewhat atypical, and only a small percentage of users are likely to be affected. Duende.AccessTokenManagement can request access tokens using the client credentials flow in several ways. In basic usage, the client credentials flow is configured once and the parameters do not vary. In more advanced situations, requests with varying protocol parameters may be made by calling specific overloads of these methods: `HttpContext.GetClientAccessTokenAsync()` and `IClientCredentialsTokenManagementService.GetAccessTokenAsync()`. There are overloads of both of these methods that accept a `TokenRequestParameters` object that customizes token request parameters. However, concurrent requests with varying `TokenRequestParameters` will result in the same token for all concurrent calls. Most users can simply update the NuGet package to the latest version. Customizations of the `IClientCredentialsTokenCache` that derive from the default implementation (`DistributedClientCredentialsTokenCache`) will require a small code change, as its constructor was changed to add a dependency on the `ITokenRequestSynchronization` service. The synchronization service will need to be injected into the derived class and passed to the base constructor. The impact of this vulnerability depends on how Duende.AccessTokenManagement is used and on the security architecture of the solution. Most users will not be vulnerable to this issue. More advanced users may run into this issue by calling the methods specified above with customized token request parameters. The impact of obtaining an access token with different than intended protocol parameters will vary depending on application logic, security architecture, and the authorization policy of the resource servers.

Patch / fix

  • nuget Duende.AccessTokenManagement 3.2.0

CISA SSVC

Exploitation
none
Automatable
yes
Technical impact
partial
Assessed
20 mo ago

Exploit prediction

0.39% chance of exploitation in the next 30 days, higher than 33% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 4.0 6.3 CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:L/VA:N/SC:L/SI:L/SA:N
CNA 4.0 6.3 CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:L/VA:N/SC:L/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Affected packages

ecosystem package affected fixed in
nuget Duende.AccessTokenManagement
<3.2.0
3.2.0

Affected products

  • DuendeSoftware foss

Classification

Weakness
  • CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.