Skip to content
Fencer Vulns
critical 9.8

CVE-2025-26410 json

Weak Hard-coded Credentials

published 2025-02-11 20 mo ago modified 2026-06-17 4 mo ago also EUVD-2025-4193

cvss
9.8
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.7%
EPSS 0.7% chance of exploitation in 30 days, percentile 54%
public exploits
0
none known

Summary

The firmware of all Wattsense Bridge devices contain the same hard-coded user and root credentials. The user password can be easily recovered via password cracking attempts. The recovered credentials can be used to log into the device via the login shell that is exposed by the serial interface. The backdoor user has been removed in firmware BSP >= 6.4.1.

Patch / fix

  • Wattsense Wattsense Bridge 6.4.1

CISA SSVC

Exploitation
Proof of concept is public
Automatable
yes
Technical impact
total
Assessed
20 mo ago

Exploit prediction

0.72% chance of exploitation in the next 30 days, higher than 54% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CISA ADP 3.1 9.8 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CNA 3.1 9.8 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Affected products

  • Wattsense Wattsense Bridge

Classification

Weakness
  • CWE-798 Use of Hard-coded Credentials

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.