Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Application Exposure of Sensitive Information Due to Incompatible Policies
published 2025-02-28 20 mo ago modified 2026-06-17 4 mo ago also EUVD-2025-5939
- cvss
- 5.3
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.3%
- EPSS 0.3% chance of exploitation in 30 days, percentile 23%
- public exploits
- 0
- none known
Summary
The Dario Health Internet-based server infrastructure is vulnerable due to exposure of development environment details, which could lead to unsafe functionality.
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSMA-25-058-01 updated cvss 5.3
Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Application
-
Dario Health Dario Application Database and Internet-based Server Infrastructure Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Applications <=5.8.7.0.36affected: mitigation “Dario Health recommends users update their Dario Health Android mobile application to the latest version. No other actions are required by users.” dariohealth.com
From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- yes
- Technical impact
- partial
- Assessed
- 20 mo ago
Exploit prediction
0.31% chance of exploitation in the next 30 days, higher than 23% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 5.3 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N |
| CNA | 4.0 | 6.9 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N |
| CNA | 4.0 | 6.9 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
Affected products
- Dario Health Dario Application Database and Internet-based Server Infrastructure
Classification
- Weakness
-
- CWE-213 Exposure of Sensitive Information Due to Incompatible Policies