Skip to content
Fencer Vulns
high 7.8

CVE-2025-23400 json

A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All vers…

published 2025-03-11 19 mo ago modified 2026-06-17 4 mo ago also EUVD-2025-7634

cvss
7.8
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.2%
EPSS 0.2% chance of exploitation in 30 days, percentile 4%
public exploits
0
none known

Summary

A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.

Patch / fix

  • Siemens Teamcenter Visualization V14.3 V14.3.0.13
  • Siemens Teamcenter Visualization V2312 V2312.0009
  • Siemens Teamcenter Visualization V2406 V2406.0007
  • Siemens Teamcenter Visualization V2412 V2412.0002
  • Siemens Tecnomatix Plant Simulation V2302 V2302.0021
  • Siemens Tecnomatix Plant Simulation V2404 V2404.0010

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-25-072-01 updated cvss 7.8

Siemens Teamcenter Visualization and Tecnomatix

  • Siemens Teamcenter Visualization V14.3 <V14.3.0.13
    affected: fixed in V14.3.0.13, mitigation
  • Siemens Teamcenter Visualization V2312 <V2312.0009
    affected: fixed in V2312.0009, mitigation
  • Siemens Teamcenter Visualization V2406 <V2406.0007
    affected: fixed in V2406.0007, mitigation
  • Siemens Teamcenter Visualization V2412 <V2412.0002
    affected: fixed in V2412.0002, mitigation
  • Siemens Tecnomatix Plant Simulation V2302 <V2302.0021
    affected: fixed in V2302.0021, mitigation
  • Siemens Tecnomatix Plant Simulation V2404 <V2404.0010
    affected: fixed in V2404.0010, mitigation

Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
total
Assessed
19 mo ago

Exploit prediction

0.16% chance of exploitation in the next 30 days, higher than 4% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 7.8 CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
CNA 4.0 7.3 CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CNA 4.0 7.3 CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Affected products

  • Siemens Teamcenter Visualization V14.3
  • Siemens Teamcenter Visualization V2312
  • Siemens Teamcenter Visualization V2406
  • Siemens Teamcenter Visualization V2412
  • Siemens Tecnomatix Plant Simulation V2302
  • Siemens Tecnomatix Plant Simulation V2404

Classification

Weakness
  • CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.