Skip to content
Fencer Vulns
low 2.3

CVE-2025-23376 json

Dell PowerProtect Data Manager Reporting, version(s) 19.16, 19.17, 19.18, contain(s) an Improper Neutralization of Special Elements Used in…

published 2025-04-28 18 mo ago modified 2026-06-17 4 mo ago also EUVD-2025-12585

cvss
2.3
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.2%
EPSS 0.2% chance of exploitation in 30 days, percentile 6%
public exploits
0
none known

Summary

Dell PowerProtect Data Manager Reporting, version(s) 19.16, 19.17, 19.18, contain(s) an Improper Neutralization of Special Elements Used in a Template Engine vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information disclosure.

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
partial
Assessed
18 mo ago

Exploit prediction

0.17% chance of exploitation in the next 30 days, higher than 6% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 2.3 CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N
NVD 3.1 4.4 CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N

Affected products

  • Dell PowerProtect Data Manager Reporting

Classification

Weakness
  • CWE-1336 Improper Neutralization of Special Elements Used in a Template Engine
  • CWE-94 Improper Control of Generation of Code

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.